News & PublicationsR & D TopicsProducts & ServicesPartners & ReferencesContactDE/EN

Rotor asymmetries - Vienna Monitoring Method


Bauwerksmonitoring

With the Vienna Monitoring Method (VMM), it is possible to detect electrical asymmetries in the rotor. This fault category includes defective rotor bars or end rings that can cause torque pulsations which are extremely difficult to detect, if at all, with conventional measuring methods. This elaborate model-based method enables the detection of defects in the rotor bar quickly and reliably under almost any operating condition. This method was made possible only by developing and implementing highly precise machine models, as well as intelligent signal processing and filtering methods